Home
Online store
Probe configurator
Contacts

Temperature

Dry Block Calibrator TA-650P - Presys

The TA-650P calibrator performs functions where three different instruments are required: dry block thermal bath, standard thermometer and calibrator for TCs, RTDs, mA, mV, ohms and thermostats. Besides these functions, they have HART® communication protocol, data logger mode, Ethernet interface and USB.
 
The new advanced line temperature calibrators are the result of more than 20 years of experience in the manufacture of dry block gauges.
Sensor calibration has never been easier thanks to the user-friendly touch-screen display. Enables rapid calibration test report retrieval without the need for specific software installation.
 
View detail

Dry well calibrator ADT875-155 - Additel

The ADT875-155 is the new dry block calibrator from Additel. With this calibrator Additel enters in the temperature calibration world. It combines excellent stability, radial and axial uniformity, quickly. With the PC option we add the 3-channel temperature reading capabilities with a process calibrator.
 
The calibrator has a range of use of -40 to 155ºC, resolution of 0,01ºC, precision of ± 0,18ºC and stability of ± 0,01ºC in full scale. The Process Calibrator (PC) option combines the many functions of a HART Process Calibrator with a Temperature Calibrator. With this option we have the ability to read a reference RTD plus 2 channels of signal mA, V, switch, RTD or thermocouple. In addition, the calibrator allows you to create tasks and HART communication. Let’s you capture screen images for future needs with the one touch of a button. Using a reference RTD it is possible to control the calibrator by the reference probe or the internal probe.



 
View detail

New ADT 286 multifunction reference thermometer - Additel

The ADT 286 is industry-first. Additel combined for the first time a high-capacity benchmark thermometer with 8.5-digit multimeter functionality.

The ADT 286 can read and record 82 temperature channels at 10 channels per second. The user can easily configure the equipment to perform field calibrations or uniformity tests, as well as a precision laboratory thermometer or 8.5-digit multimeter. The base unit comes with two precision reading channels that can be used to measure SPRT. Modules capable of measuring 10 RTD's, PRT's or thermistors and 20 thermocouples each can be added. The expansion can be made up to 82 channels.
 
View detail
  • 0
  • 1
We use our own and third-party cookies to offer you a better experience and service. To know which cookies we use and how to disable them, read the cookies policy.
By ignoring or closing this message, and unless you have disabled cookies, you agree to its use on this device.