Dust concentration measuring system DUSTHUNTER T200 – Sick

Dust concentration measuring system.

The DUSTHUNTER T200 is a type-approved measuring device for dust at medium to high concentrations. Basic measuring value is transmittance. Opacity and extinction can be calculated and displayed as well as the dust concentration after gravimetric calibration. Furthermore, it has an integrated contamination check of the sender-receiver and reflector unit as well as an automatic self-alignment of the optical assembly.
View detail

Dust monitor in wet flue gas FWE200DH - Sick

Reliable dust measurement in wet gases.
 
The FWE200DH dust measuring device is designed to continuously measure dust concentrations in wet flue gas. The gas is extracted via a sampling probe and heated above dew point. Droplets in the gas are vaporized, making it impossible for them to falsify the measurement results. The highly sensitive scattered light measurement principle enables even very low dust concentrations to be measured.

The FWE200DH meets the requirements of EN 14181 and EN 15267.
 
View detail

Dust monitor with two measuring principles DUSTHUNTER C200 - Sick

Dust monitor with two measuring principles.

The DUSTHUNTER C200 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust concentrations.

The automatic self-alignment optimizes the position of the measuring beam and prevents incorrect measurement. An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.
View detail

Particle and flow analyzer Combiprobe CP100 - Sick

Combined measurement of dust, volume flow, pressure, and temperature.
 
The Combiprobe CP100 is the combination of a DUSTHUNTER SP100 scattered light dust measuring device and a FLOWSIC100 PR volume flow measuring device on a flange plate. The combined probe also features a pressure transmitter and a resistance thermometer. The Combiprobe CP100 only requires a single mounting opening in the funnel in order to measure the dust concentration, volume flow, pressure and temperature. This means that there is considerably less outlay on installation than if the individual components were to be installed separately.
 
View detail

Particles analyser DUSTHUNTER SB50 - Sick

Scattered light dust monitor with backward scattering.

The DUSTHUNTER SB50 is a measuring device for dust at low to high concentrations in challenging applications, e.g. in hot or corrosive gases. The measurement is based on the backward scattering of light. Installation is made from one side only. Two different penetration depths are possible. Automatic compensation of background light, therefore no light absorber necessary.
View detail

Particles analysers DUSTHUNTER SB100 - Sick

Scattered light dust monitor with backward scattering.

The DUSTHUNTER SB100 is a type-approved measuring device for dust at very low to high concentrations in challenging applications, e.g. in hot or corrosive gases. The measurement is based on the backward scattering of light. Installation is made from one side only.
Two different penetration depths are possible. Automatic compensation of background light, therefore no light absorber necessary. An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.

At a glance For very low to high dust concentrations; One-side installation; Contamination monitoring; Automatic check of zero and reference point; Automatic compensation of background radiation, therefore no light absorber necessary; For medium to large duct diameters.
View detail

Particles analysers DUSTHUNTER SF100 - Sick

Scattered light dust monitor with forward scattering.

The DUSTHUNTER SF100 is a type-approved measuring device for dust at very low to high concentrations along the whole duct diameter. The measurement is based on the forward scattering of light. The automatic self-alignment optimizes the position of the measuring beam and prevents incorrect measurement. An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.

At a glance For very low to high dust concentrations; Contamination monitoring; Automatic check of zero and reference point; Automatic self-alignment; For small to medium duct diameters.
View detail