Dust monitor in wet flue gas FWE200DH - SICK
Reliable dust measurement in wet gases.
The FWE200DH dust measuring device is designed to continuously measure dust concentrations in wet flue gas. The gas is extracted via a sampling probe and heated above dew point. Droplets in the gas are vaporized, making it impossible for them to falsify the measurement results. The highly sensitive scattered light measurement principle enables even very low dust concentrations to be measured.
The FWE200DH meets the requirements of EN 14181 and EN 15267.
The FWE200DH dust measuring device is designed to continuously measure dust concentrations in wet flue gas. The gas is extracted via a sampling probe and heated above dew point. Droplets in the gas are vaporized, making it impossible for them to falsify the measurement results. The highly sensitive scattered light measurement principle enables even very low dust concentrations to be measured.
The FWE200DH meets the requirements of EN 14181 and EN 15267.


Dust monitor with two measuring principles DUSTHUNTER SP100 - SICK
Exhaust gases from cement production or similar applications are usually loaded with dust particles. Environmental protection legislation requires that the dust is removed before the gas is released into the atmosphere.
The SICK dust monitor DUSTHUNTER SP100 measures even low dust concentrations and thus detects any filter errors. An automatic zero and reference point check is integrated to reduce the need for maintenance.
The SICK dust monitor DUSTHUNTER SP100 measures even low dust concentrations and thus detects any filter errors. An automatic zero and reference point check is integrated to reduce the need for maintenance.


Particle and flow analyzer Combiprobe CP100 - SICK
Combined measurement of dust, volume flow, pressure, and temperature.
The Combiprobe CP100 is the combination of a DUSTHUNTER SP100 scattered light dust measuring device and a FLOWSIC100 PR volume flow measuring device on a flange plate. The combined probe also features a pressure transmitter and a resistance thermometer. The Combiprobe CP100 only requires a single mounting opening in the funnel in order to measure the dust concentration, volume flow, pressure and temperature. This means that there is considerably less outlay on installation than if the individual components were to be installed separately.
The Combiprobe CP100 is the combination of a DUSTHUNTER SP100 scattered light dust measuring device and a FLOWSIC100 PR volume flow measuring device on a flange plate. The combined probe also features a pressure transmitter and a resistance thermometer. The Combiprobe CP100 only requires a single mounting opening in the funnel in order to measure the dust concentration, volume flow, pressure and temperature. This means that there is considerably less outlay on installation than if the individual components were to be installed separately.


Particles analyser DUSTHUNTER SB50 - SICK
Scattered light dust monitor with backward scattering.
The DUSTHUNTER SB50 is a measuring device for dust at low to high concentrations in challenging applications, e.g. in hot or corrosive gases. The measurement is based on the backward scattering of light. Installation is made from one side only. Two different penetration depths are possible. Automatic compensation of background light, therefore no light absorber necessary.
The DUSTHUNTER SB50 is a measuring device for dust at low to high concentrations in challenging applications, e.g. in hot or corrosive gases. The measurement is based on the backward scattering of light. Installation is made from one side only. Two different penetration depths are possible. Automatic compensation of background light, therefore no light absorber necessary.


Particles analysers DUSTHUNTER SB100 - SICK
Scattered light dust monitor with backward scattering.
The DUSTHUNTER SB100 is a type-approved measuring device for dust at very low to high concentrations in challenging applications, e.g. in hot or corrosive gases. The measurement is based on the backward scattering of light. Installation is made from one side only.
Two different penetration depths are possible. Automatic compensation of background light, therefore no light absorber necessary. An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.
At a glance For very low to high dust concentrations; One-side installation; Contamination monitoring; Automatic check of zero and reference point; Automatic compensation of background radiation, therefore no light absorber necessary; For medium to large duct diameters.
The DUSTHUNTER SB100 is a type-approved measuring device for dust at very low to high concentrations in challenging applications, e.g. in hot or corrosive gases. The measurement is based on the backward scattering of light. Installation is made from one side only.
Two different penetration depths are possible. Automatic compensation of background light, therefore no light absorber necessary. An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.
At a glance For very low to high dust concentrations; One-side installation; Contamination monitoring; Automatic check of zero and reference point; Automatic compensation of background radiation, therefore no light absorber necessary; For medium to large duct diameters.


Scattered light dust measuring devices DUSTHUNTER SP30 - SICK
Measure intelligently. Reduce costs.
The Dusthunter SP30 is a measuring device which reliably detects very low to high dust content.
The measurement is based on the forward scattering of light and is independent of the gas velocity and particle charge. The automated monitoring of the zero and reference point ensures a high level of accuracy.
The Dusthunter SP30 is a measuring device which reliably detects very low to high dust content.
The measurement is based on the forward scattering of light and is independent of the gas velocity and particle charge. The automated monitoring of the zero and reference point ensures a high level of accuracy.