Stand-Alone Relay Module REL04SA - Qbus
This module with 4 outputs and 5 inputs is the base of the Qbus Stand-Alone range and functions both autonomously - so without controller, without external power supply and without any configuration - but can also be connected to a controller to become part of a full-fleged Qbus installation.
Input 1 to 4 control respectively output 1 to 4. Input 5 (A) is a scene-input which executes an ALL off scene when pushing for 0,7 seconds, or a panic scene, all outputs on when pushing the button for 3 seconds.
Input 1 to 4 control respectively output 1 to 4. Input 5 (A) is a scene-input which executes an ALL off scene when pushing for 0,7 seconds, or a panic scene, all outputs on when pushing the button for 3 seconds.
more details
Downloads
Request Offer
The REL04SA contains 4 outputs of each max 16A to control lighting, shutters, power plugs…
For shutter/blind/curtain control, the REL04SA needs to be set in “Shutter mode”.
For heavy inductive loads (many fluorescente lights) with a high capacity or bipolar application, contactors need to be added.
It is also possible to configure a REL04SA module via a Qbus controller and then take the controller away. This way, the relay contacts can be configured with a delay ON, delay OFF and TIME OFF function. Keep in mind that besids the TIME-OFF function, no other timers are possible in Stand-Alone mode. Using the controller, the inputs can be set as Normal Open, Normal Closed, Pushbutton.
Features
Advantages
Industries
F.Fonseca is the representative of Qbus in Portugal.
For shutter/blind/curtain control, the REL04SA needs to be set in “Shutter mode”.
For heavy inductive loads (many fluorescente lights) with a high capacity or bipolar application, contactors need to be added.
It is also possible to configure a REL04SA module via a Qbus controller and then take the controller away. This way, the relay contacts can be configured with a delay ON, delay OFF and TIME OFF function. Keep in mind that besids the TIME-OFF function, no other timers are possible in Stand-Alone mode. Using the controller, the inputs can be set as Normal Open, Normal Closed, Pushbutton.
Features
- Power supply: 230Vac +-10%, 50 Hz – maximum protection 16A/2P;
- Insulation voltage: 3 kVac tested;
- Characteristic consumption: 9VA maximum – all relays on;
- Working temp. range: 10°C to 50°C;
- Storage temp. range: -10°C to 60°C;
- Maximum humidity: 93%, no moisture condensation;
- Bus load: 10mA at nominal 13,8V;
- Internal fuse: 500mA single-phase;
- Max installation altitude: 2.000 meters.
Advantages
- Modules equipped with internal power suply;
- Pushbuttons on the module for manual operation;
- Inputs for connection os standard pushbuttons without need external power supply.
- No programming or configuration required;
- Connectors for connection of the Qbus home Automation system (complete system).
Industries
- Electrical installers;
- Construction companies;
- Electrical design offices.
F.Fonseca is the representative of Qbus in Portugal.