In/out Modules

Analogue control module – ANR04SA - Qbus

This module with 4 analog dimmers with relays and 5 inputs is the most multifunctional module of the Qbus Stand Alone range. This module can both switch and dim (even with constant light control) and can function both autonomously – so WITHOUT Controller, WITHOUT external power supply and WITHOUT any configuration – but can also be connected to a Controller to become part of a full-fledged Qbus installation.
 
The ANR04SA is suitable for controlling four analog dimmers (0/1-10V or PWM) or relays (16A each) or a combination of both. Each analog dimmer controls a relay contact which switches off when the analog dimmer is at 0%. These dimmers can be used the control LEDs, Fluorescent Tubular lamps, ventilators,… It is also possible to use the relay output as an ON/OFF switching contact to control lights, sockets,… And all of this without controller and configuration.

 

In module - INP04 - Qbus

Module for connecting external contacts such as regular switches and push buttons, solar/wind detector, motion detector, smoke detectors,…

On the INP04, 4 potential free contacts and 4 low current LEDs (2mA without serial resistor) can be connected. The maximum length of the conductor between the INP04 and the potential free input is 20 meters. The cable type or its section is irrelevant.
 

In module INP02 - Qbus

Module for connecting external contacts such as regular switches and push buttons, solar/wind detector, motion detector, smoke detectors, …

On the INP02, 2 potencial free contacts and 2 low corrent LEDs (2mAwithout serial resistor) can be connected. The maximum length of the conductor between the INP02 and the potencial free input is 20 meters. The cable type or its section is irrelevant.
 

In/Out module - ROL01 - Qbus

The ROL01 is a decentral module, suitable for switching 1 motor and contains a connector to which two potential free inputs (e.g. pushbuttons) can be connected. The module fits in a standard flush-mounted socket which guarantees easy connection with potential push-buttons and the outputs.

The relay module has 2 potential-free contacts (1 UP, 1 DOWN) which can control 1 motor of max 3,5A at 230V (cosj=1) / 30 Vdc.
 

In/Out module REL02 - Qbus

The REL02 is a decentralmodule, suitable for switching 2 circuits and contains a conector to which two potencial free inputs (e.g. push buttons) can be connected. The module fits in a standard flush-mouted socket which guarantees easy connectionwith potencial push-buttons and the outputs.

The relay module has 2 potencial-free, normally open contacts which can each connect max. 8A at 230V (cos ɸ = 1) / 30Vdc.
 

Input module INP08 - Qbus

Module for DIN-rail, for connecting external contacts such as regular switches and push buttons, solar/wind detector, motion detector, smoke detectors.
Eight optical isolated inputs are provided, which must be potencial-free.

The INP08 can have 8 optically disconnected potencial-free inputs. The maximum length of each inputs is 200 meters. The cable type or it’s section is irrelevante.
 

Input module INP08/230 - Qbus

Module for DIN-rail, for connecting external contacts such as solar/wind detector, motion detector, door switches and push buttons. There are 8 optically insulated inputs. Each input needs a voltage to be active, the voltage can be 12V ou 230V. If there are inputs with potential-free contacts they can be connected to the module via the 12Vac connection at the botton of the module.
 
 

Input module INP16 - Qbus

Module for DIN-rail, for connecting external contacts such as regular switches and push buttons, solar/wind detector, motion detector, smoke detectors.
Sisteen optical isolated inputs are provided, which must be potencial-free.

The INP16 can have 16 optically disconnected potencial-free inputs. The maximum length of each inputs is 200 meters. The cable type or it’s section is irrelevante.
 

Module for DIN-rail relay REL08 - Qbus

Module for DIN-rail, suitable for switching eight devices. The relay module has 8 potential-free, change over contacts which can each connect max 16A at 230V (cosj=1). These are 8 independently working contacts that can each be allocated an individual function by means of the software.
The relay module does not have any specific function. It can handle all switching functions : mono-stable (bell), bi-stable (on/off), timer, interval, shutter operation, blinds etc.

Therefore this module can be combined for motor controls and for lighting.
In the case of heavy inductive loads (TL lamp transformers) with a high capacity or bipolar applications, contactors need to be added. The relay module contact then activates the coil of the contactor.
 

Shutter module ROL02P - Qbus

Module for DIN-rail, suitable for switching and positioning 2 shutters / blinds / curtains. The shutter module has 2 up/down outputs (2 shutters can be connected on a ROL02P module). The shutter motors that can be connected to the ROL02P need to be 230Vac motors, with a minimum load of 40VA and a maximum load of 500VA. The shutters also need to have limit contacts, as this will be important for the calibration of the shutters. The ROL02P will not allow mutual signals on UP1(/UP2) and DN1(/DN2) when activating the 2 outputs at the same time.
 

Stand-Alone Relay Module REL04SA - Qbus

This module with 4 outputs and 5 inputs is the base of the Qbus Stand-Alone range and functions both autonomously - so without controller, without external power supply and without any configuration - but can also be connected to a controller to become part of a full-fleged Qbus installation.
Input 1 to 4 control respectively output 1 to 4. Input 5 (A) is a scene-input which executes an ALL off scene when pushing for 0,7 seconds, or a panic scene, all outputs on when pushing the button for 3 seconds.

Universal Dimmer DIM02SA/500U - Qbus

The DIM02SA/500U can dim up to 2 circuits of each 10-500VA and can handle halogen spots, electronic & magnetic transfo's, incandescent lamps, dimmable CFL's and 230V LEDs. The Universal Dimmer DIM02SA/500U from Qbus has an internal protection against short circuits, overload and overheating and has a built-in CRC-filter. This module can also be used Stand-Alone (without Qbus Controller) as it contains 3 inputs to connect standard pushbuttons (including All Off and Panic button).

The DIM02SA/500U module also has 3 potential-free inputs to connect standard push buttons. Input 1 to 2 control respectively output 1 to 2, input 3 (A) is a scene input which executes an ALL-OFF-scene when pushing for 0,7 seconds (and then releasing the button), or a panic-scene (all outputs on) when pushing the button for 3 seconds. The inputs are set standard in push button mode. When the module is connected to a controller, the input mode of the DIM02SA/500U can be changed to Normal Open, Normal Closed or toggle.
 

Universal Dimmer DIM04SA/500U - Qbus

The universal dimmer DIM04SA/500U from Qbus can dim up to 4 circuits of each 10-500VA, and can handle halogen spots, electronic & magnetic transfo's, incandescent lamps, dimmable CFL's and 230V LEDs. The DIM04SA/500U has an internal protection against short circuits, overload and overheating and has a built-in CRC-filter. This module can also be used Stand-Alone (without Qbus Controller) as it contains 5 inputs to connect standard pushbuttons (including All Off and Panic button).
 
The universal dimmer DIM04SA/500U from Qbus has 5 potencial-free inputs to connect standard push buttons. Input 1 to 4 control respectively output 1 to 4, input 5 (A) is a scene input which executes an ALL-OFF-scene when pushing for 0,7 seconds (and then releasing the button), or a panic-scene (All outputs on) when pushing the button for 3 seconds. The inputs are set standard in push button mode. When the module is connected to a controller, the input mode of the DIM04SA/500U can be changed to Normal Open, Normal Closed or toggle.
 