Temperature

ADT286 multifunction reference thermometer - Additel

The ADT286 is industry-first. Additel combined for the first time a high-capacity benchmark thermometer with 8.5-digit multimeter functionality.

The ADT286 can read and record 82 temperature channels at 10 channels per second. The user can easily configure the equipment to perform field calibrations or uniformity tests, as well as a precision laboratory thermometer or 8.5-digit multimeter. The base unit comes with two precision reading channels that can be used to measure SPRT. Modules capable of measuring 10 RTD's, PRT's or thermistors and 20 thermocouples each can be added. The expansion can be made up to 82 channels.
 

Dry Block Calibrator TA-650P - Presys

The TA-650P calibrator performs functions where three different instruments are required: dry block thermal bath, standard thermometer and calibrator for TCs, RTDs, mA, mV, ohms and thermostats. Besides these functions, they have HART® communication protocol, data logger mode, Ethernet interface and USB.
 
The new advanced line temperature calibrators are the result of more than 20 years of experience in the manufacture of dry block gauges.
Sensor calibration has never been easier thanks to the user-friendly touch-screen display. Enables rapid calibration test report retrieval without the need for specific software installation.
 

Dry block calibrator TE-1200P- Presys

The Presys TE-1200P dry-block calibrator shows that excellent performance at a reduced cost is possible, offering features that can only be found in competing models of much higher cost. Robust and compact, it generates temperatures from 50ºC to 1200ºC, with an accuracy of ±3.8ºC, stability of ±0.3ºC and resolution of 0.01ºC.
 

Dry block calibrator TE-350P- Presys

The Presys TE-350P dry block calibrator shows that excellent performance at a reduced cost is possible, offering features that can only be found in competing models of much higher cost. Robust and compact, it generates temperatures from room temperature to 350ºC, with an accuracy of ±0.131ºC + 0.13% reading, stability of ±0.05ºC and resolution of 0.01ºC.
 
 

Dry block calibrator TE-650P- Presys

The TE-650P block calibrator from Presys shows that excellent performance at a reduced cost is possible, offering features that can only be found in competing models of much higher cost. Robust and compact, it generates temperatures from room temperature to 650ºC, with an accuracy of ±0.13ºC + 0.13% of reading, stability of ± 0.1ºC and resolution of 0.01ºC.
 

Dry well calibrator ADT875-1210 - Additel

ADT875-1210 is the new dry block calibrator from Additel for temperatures up to 1210ºC. With this calibrator, Additel reinforces its line of dry block calibrators. It combines excellent stability, radial and axial uniformity, with speed. With the PC option was added the ability to read 4 temperature channels with a process calibrator. In the higher precision
ADT878 series, the values of axial and radial accuracy and uniformity improve in order to obtain reference performances in the calibration of thermocouples.
 

Dry well calibrator ADT875-155 - Additel

The ADT875-155 is the new dry block calibrator from Additel. With this calibrator Additel enters in the temperature calibration world. It combines excellent stability, radial and axial uniformity, quickly. With the PC option we add the 3-channel temperature reading capabilities with a process calibrator.



 

Dual-channel reference thermometer ADT282 - Additel

Additel’s ADT282 reference thermometer readout delivers the best possible accuracies and features in the palm of your hand!
 
With precision capability on par with laboratory thermometers, the ADT282 is capable of handling the most demanding measurements. The dual-channel analog design makes it easy to compare ultra-accurate measurements and meets all your temperature measurement needs.
The easy-to-use touch screen makes navigating between menus very fast, providing a very pleasant user experience. Lemo-style smart plugs ensure that all calibration information for your probes is always available.
 

High temperature furnace TA-1200PLAB - Presys

The TA-1200PLAB is a high-temperature, high-volume laboratory furnace. With above-class uniformity and stability, it will dramatically reduce uncertainty in your thermocouple calibrations.
 
The TA-1200PLAB has 3 control zones. This segmentation makes this furnace a reference in terms of precision and homogeneity. With this control, we have better temperature distribution across the block and thus ensure uniform radial and axial uniformity throughout the 100mm measuring zone.

Infrared calibator T-500PIR - Presys

The T-500PIR is the ideal tool for the calibration of infrared sensors. 
With a temperature range from ambiente to 500ºC, teh T-500PIR alows you to test and calibrate of most ifrared thermometers in the industry.
The large 80mm target, with excelente temperature uniformity on the whole surface, garantees the necessary area for calibrations.
 

Infrared thermometer calibrator T-30NIR-H- Presys

The T-30NIR-H calibrator is the ideal tool for the calibration of infrared sensors for measuring body temperature.
 
With a temperature range of 20º to 45ºC, the T-30NIR-H facilitates the calibration of infrared thermometers, given that the temperatures generated are close to the temperature of the human body. You have the possibility to work with an external sensor, which allows you to change the accuracy from ± 0.1ºC to ± 0.05ºC and thus add accuracy to your calibrations. The resolution is ± 0.01ºC and the stability is ± 0.1ºC. The 80mm target guarantees an emissivity of 0.98 (± 0.01).
 

Laboratory calibration furnace ADT850-1200 - Additel

The Additel ADT850-1200 thermocouple calibration furnace, with a temperature range from 300°C to 1200°C, is the answer for anyone looking to save time, costs and space in their calibration laboratory.
 
The demands of thermocouple calibration and the number of equipment required led to the development of the ADT850-1200, which combines the functionality of 3 furnaces in one piece of equipment. The user can choose optimized settings for short probes, longer probes and even for annealing purposes.

 
  • 0