Coriolis mass flowmeter TME/UMC4 - Kobold

High performance at an economical price.

The Kobold TME Series general purpose Coriolis mass flowmeter from KOBOLD Instruments is a very accurate, rugged design built for general purpose mass flow measurements of liquids and gases in most chemical, petrochemical, oil and gas applications.

Mass flow, density and temperature are simultaneously measured, and volumetric flow is computed from these parameters. The flowmeter’s wetted materials (flanges and measuring tubes) are available in 316L stainless steel. The measuring tubes and sensors are protected by a very rugged cast iron housing.
View detail

Differential pressure flow meter/monitor – RCD - Kobold

The Kobold flow meter model RCD is used for measuring and monitoring liquid and gas flows. The device works on the well-known principle of the Venturi nozzle. A small pressure difference proportional to the flow is produced by the flowing medium at an orifice constriction (nozzle) in the device housing.

The shape of the nozzle is based on the flow, whereby the flow characteristic remains constant over the entire measuring range. Drill holes are located in the housing fitting to absorb the resulting differential pressure and transfer it to a differential-pressure measuring cell fitted in the housing.
 
View detail

Electromagnetic flow meters FLONET FH20XX - Elis Plzen

Induction flow meters/ electromagnetic flow meters are intended for industrial measurements of electrically conductive liquids in different fields of industry. Induction flow meters meet most demanding requirements on accuracy, reliability and long-term stability of measurements. Liquid flow rate measurements in both directions of flow are possible.

The liquid flow is measured in a contactless manner; the flow meter has no moving mechanical parts and the hydrodynamic conditions at the measurement location in the pipe are absolutely unaffected.
Induction flow meters of the FLONET FH20XX type series from Elis are intended for professional application and measurement of flow rates of electrically-conductive liquids in water and heat-supply systems, food-processing and chemical industries. They meet the most demanding requirements on high measurement accuracy, long-term stability and hygienic standard.
View detail

Electromagnetic flow meters FLONET FH20XX - Elis Plzen

Induction flow meters/ electromagnetic flow meters are intended for industrial measurements of electrically conductive liquids in different fields of industry. Induction flow meters meet most demanding requirements on accuracy, reliability and long-term stability of measurements. Liquid flow rate measurements in both directions of flow are possible.

The liquid flow is measured in a contactless manner; the flow meter has no moving mechanical parts and the hydrodynamic conditions at the measurement location in the pipe are absolutely unaffected.
View detail

Flow meter paddle torsional type DPT- kobold

The paddle torsional flow meter type DPT from kobold works with practically no wear and tear. A flat torsion spring fastening the paddle provides the elastic force, and forms the basis of the measuring principle. The deflection of the lever arm is transferred through a magnet to a Hall-effect sensor in a non-contacting fashion. This technology has important advantages: the devices operate independent of the operating pressure. Friction loss during paddle deflection causes no switching hysteresis. 
 
View detail

Flowmeter and counter for liquids and gases BGN - kobold

The Kobold BGN meter is suitable for flow measurement of liquid or gaseous products in pipes. It shows the current flow rate in volume or mass per unit in time. 

The Kobold BGN Series variable area flowmeter functions by the fluid flowing from bottom to top through the meter tube of the flowmeter. The float is lifted until an annular gap between the meter ring and the cone-shaped float is produced which corresponds to the flow. The forces acting on the float are in equilibrium. The forces that are mainly acting on the float comprise buoyancy according to the principle of Archimedes, the flow force of the medium and the weight force. Each position of the float corresponds to a flow value measured during calibration, which is transferred to a scale. The BGN variable area flowmeter consists of a meter tube with connections, a meter ring, and a conical float. By means of a magnet, the position of the float is transferred to an encapsulated follow magnet, which has been fitted to a pointer axle. The position of a second annular follow magnet fitted on the pointer axle is transferred to the scale by means of the pointer.
View detail

Variable area flowmeter glass cone UVR/UTR - Kobold

The flow meters and switches model UVR and UTR for liquids and air operate on suspended float principle: that is, the installation position is vertical and the direction of flow is from bottom to top.

The instruments have been designed as simple and thus economical measuring systems. The float for UVR and UTR is a bomb from float, whereby the indication point is the top of float. The appliance is available with or without needle valve as well.
View detail