Login
MyFFonseca
If you do not have an account MyFFonseca, please register and get access to exclusive content to registered users!
Create registryLogin
MyFFonseca
If you do not have an account MyFFonseca, please register and get access to exclusive content to registered users!
Create registry
Combustion gas analysers Testo 330i
Proven technology meets revolutionary operation
The Combustion gas analysers Testo 330i flue gas analyzer advanced set will enable you to overcome all the challenges that crop up when commissioning and servicing heating systems. The Combustion gas analysers Testo 330i advanced set contains the flue gas analyzer, a flue gas probe and a temperature probe, along with practical accessories.
The Combustion gas analysers Testo 330i flue gas analyzer advanced set will enable you to overcome all the challenges that crop up when commissioning and servicing heating systems. The Combustion gas analysers Testo 330i advanced set contains the flue gas analyzer, a flue gas probe and a temperature probe, along with practical accessories.
BIOGAS analyser Multitec 545 - Sewerin
Multi-gas measuring device with infrared sensors and extended measuring range for hydrogen sulphide.
With the Multitec 545, up to five gases can be measured simultaneously. The very high H2S concentrations in wastewater treatment plants and palm oil factories, for example, place special demands on the measuring instrument. With its rugged design and wide H2S measuring range, the Multitec 545 is ideal for this use.
With the Multitec 545, up to five gases can be measured simultaneously. The very high H2S concentrations in wastewater treatment plants and palm oil factories, for example, place special demands on the measuring instrument. With its rugged design and wide H2S measuring range, the Multitec 545 is ideal for this use.
BIOGAS analyzer Multitec® BioControl 2 - Sewerin
The entry-level model for individual process optimization.
The BIOGAS analyser Multitec® BioControl2 da Sewerin is a unique measuring system comprising a fixed stationary unit and a mobile gas measuring device. It is used in small to medium-sized BIOGAS plants, landfills, wastewater treatment plants and composting plants.
The BIOGAS analyser Multitec® BioControl2 da Sewerin is a unique measuring system comprising a fixed stationary unit and a mobile gas measuring device. It is used in small to medium-sized BIOGAS plants, landfills, wastewater treatment plants and composting plants.
BIOGAS measuring analyser Multitec 540 – Sewerin
Combined stationary measuring device with mobile gas meter.
The Multitec® BioControl is a combined measuring device consisting of the Multitec® BioControl fixed installation and a mobile gas measuring device, namely the Multitec® 540.
Depending on the version of Multitec® BioControl, the gas composition and volume can be automatically measured and monitored at up to eight measurement locations. The Multitec® 540 measures the values at the individual measurement locations sequentially. The values are transferred to the Multitec® BioControl via an interface.
The mobile gas measuring device must be regularly maintained to guarantee accurate measuring results. The Multitec® BioControl allows easy maintenance for the versions with four and eight measurement locations as standard, with automatic calibration and adjustment with test gas.
The Multitec® BioControl is a combined measuring device consisting of the Multitec® BioControl fixed installation and a mobile gas measuring device, namely the Multitec® 540.
Depending on the version of Multitec® BioControl, the gas composition and volume can be automatically measured and monitored at up to eight measurement locations. The Multitec® 540 measures the values at the individual measurement locations sequentially. The values are transferred to the Multitec® BioControl via an interface.
The mobile gas measuring device must be regularly maintained to guarantee accurate measuring results. The Multitec® BioControl allows easy maintenance for the versions with four and eight measurement locations as standard, with automatic calibration and adjustment with test gas.
Bus-capable connection digiLine - Jumo
Intelligent, bus-capable connection system for digital sensors in liquid analysis.
With JUMO digiLine, JUMO presents a bus-compatible connection system for digital sensors in liquid analysis which also offers Plug and Play functionality.
JUMO digiLine Opens the Door to Sensor Technology 4.0
JUMO digiLine enables simple construction of sensor networks in which sensors are connected to each other in a star or tree structure. A single shared signal line is used for communication with the next evaluation unit or controller. This way plants in which several parameters need to be measured at the same time in different places can be wired efficiently and quickly.
With JUMO digiLine, JUMO presents a bus-compatible connection system for digital sensors in liquid analysis which also offers Plug and Play functionality.
JUMO digiLine Opens the Door to Sensor Technology 4.0
JUMO digiLine enables simple construction of sensor networks in which sensors are connected to each other in a star or tree structure. A single shared signal line is used for communication with the next evaluation unit or controller. This way plants in which several parameters need to be measured at the same time in different places can be wired efficiently and quickly.
Combustion gas analysers – Control Unit Testo 350
The control unit with the large graphic display is the element of display and control of the Testo 350.
Can be removed and the base is equipped with a rechargeable lithium battery. All settings are performed using the cursor. The presentation of measurement values is performed through multi-color graphics display. Thanks to the internal memory, the measurement data can be downloaded from the box analysis to the control unit. If necessary, can be used and controlled several boxes of analysis using only one control unit.
Can be removed and the base is equipped with a rechargeable lithium battery. All settings are performed using the cursor. The presentation of measurement values is performed through multi-color graphics display. Thanks to the internal memory, the measurement data can be downloaded from the box analysis to the control unit. If necessary, can be used and controlled several boxes of analysis using only one control unit.
Compact multichannel transmitter/controller - dTRANS pH 02 - Jumo
The Jumo dTRANS pH 02 is a compact, modular instrument, that has the flexibility (with 3 slots, optional boards, etc.,) to accomplish a wide range of tasks.
The main input of the Jumo dTRANS pH 02 is designed for sensors to measure the pH value or the redox voltage - both conventional glass sensors and ISFET sensors can be connected - or the concentration of ammonia. PT100 or PT1000 resistance thermometers, NTC/ PTC or 0(4) to 20 mA and 0 to 10 V standard signals can be connected to the second analog input (compensating input). The two binary inputs can be used both as the initiators for actions (such as HOLD, keyboard inhibit), and for flow rate measurement, when pulse generators (such as impeller sensors) are connected. The high-contrast, graphic display allows the input signals to be visualized by numbers or as a bar graph. Parameters are displayed in plain text for easily comprehensible and secure operation.
The main input of the Jumo dTRANS pH 02 is designed for sensors to measure the pH value or the redox voltage - both conventional glass sensors and ISFET sensors can be connected - or the concentration of ammonia. PT100 or PT1000 resistance thermometers, NTC/ PTC or 0(4) to 20 mA and 0 to 10 V standard signals can be connected to the second analog input (compensating input). The two binary inputs can be used both as the initiators for actions (such as HOLD, keyboard inhibit), and for flow rate measurement, when pulse generators (such as impeller sensors) are connected. The high-contrast, graphic display allows the input signals to be visualized by numbers or as a bar graph. Parameters are displayed in plain text for easily comprehensible and secure operation.
Conductive and inductive conductivity sensor digiLine CR e Ci - Jumo
Digital measurement of inductive and conductive conductivity, now with IO-Link.
Another step in Jumo’s intelligent measurement technology with new conductivity sensors, which expand JUMO’s transmitters range for digiLine digital communication bus.
The new smart transmitters are available in various mechanical and electrical installation configurations, perfectly adjusted for each application, with inductive and conductive sensors to measure electrolytic conductivity.
Another step in Jumo’s intelligent measurement technology with new conductivity sensors, which expand JUMO’s transmitters range for digiLine digital communication bus.
The new smart transmitters are available in various mechanical and electrical installation configurations, perfectly adjusted for each application, with inductive and conductive sensors to measure electrolytic conductivity.
Conductive two-electrode conductivity sensor BlackLine CR-GT/-EC/-GS - JUMO
This conductivity sensor from the BlackLine family is available in versions GT, EC, and GS.
The GT version features a special graphite as the electrode material. The graphite has been especially treated to achieve - in conjunction with suitable evaluation devices – measuring ranges up to 100 mS/cm and above.
A temperature probe can optionally be integrated. The conductivity sensor with 120 mm fitting length and a shaft diameter of 12 mm can be used in combination with standard pH or redox electrodes in suitable built-in fittings. The sensor is also ideally suited for linking with handheld or laboratory measuring equipment. When used as an online sensor, suitable flow-through fittings must be employed.
The GT version features a special graphite as the electrode material. The graphite has been especially treated to achieve - in conjunction with suitable evaluation devices – measuring ranges up to 100 mS/cm and above.
A temperature probe can optionally be integrated. The conductivity sensor with 120 mm fitting length and a shaft diameter of 12 mm can be used in combination with standard pH or redox electrodes in suitable built-in fittings. The sensor is also ideally suited for linking with handheld or laboratory measuring equipment. When used as an online sensor, suitable flow-through fittings must be employed.
Conductive two-electrode conductivity sensor tecLine CR - Jumo
The tecLine CR conductivity sensors from Jumo are used in conjunction with suitable transducers to define the electrolytic conductivity in liquids. These sensors work according to the 2-electrode principle. The transducer supplies them with alternating voltage, and the current that is carried through the liquid and the electrodes is defined by the medium's conductivity.
Conductivity sensor for water technology ecoLine Ci – JUMO
The sensor detects the electrolytic conductivity of a process liquid. It uses the inductive principle of measurement. Because it uses the inductive method of measurement rather than the conductive 2-pin or 4-pin measurement method, the sensor is virtually maintenance-free.
The sensor detects the electrolytic conductivity of a process liquid and the measuring accuracy is practically unaffected by accumulations and grease or oil film on the surface of the sensor.
A (Pt1000) temperature sensor acquires the process temperature at the same time. The temperature sensor can either be exposed in a stainless-steel pocket (ultra-fast response) or be located right inside the plastic body (with PVDF, only the internal option is possible).
The sensor detects the electrolytic conductivity of a process liquid and the measuring accuracy is practically unaffected by accumulations and grease or oil film on the surface of the sensor.
A (Pt1000) temperature sensor acquires the process temperature at the same time. The temperature sensor can either be exposed in a stainless-steel pocket (ultra-fast response) or be located right inside the plastic body (with PVDF, only the internal option is possible).
Digital optical sensor digiLine O-DO S10 - Jumo
Jumo digiLine O-DO S10 the digital optical sensor for dissolved oxygen in aqueous solutions.
The sensor's latest optical technology enables precise measurement with long-term stability in fish breeding, sewage treatment plants, as well as other water and wastewater technology applications. The integrated analog and digital interface allows easy connection to field devices and process control systems.
The sensor's latest optical technology enables precise measurement with long-term stability in fish breeding, sewage treatment plants, as well as other water and wastewater technology applications. The integrated analog and digital interface allows easy connection to field devices and process control systems.
Dust monitor in wet flue gas FWE200DH - Endress+Hauser
Reliable dust measurement in wet gases.
The FWE200DH dust measuring device is designed to continuously measure dust concentrations in wet flue gas. The gas is extracted via a sampling probe and heated above dew point. Droplets in the gas are vaporized, making it impossible for them to falsify the measurement results. The highly sensitive scattered light measurement principle enables even very low dust concentrations to be measured.
The FWE200DH meets the requirements of EN 14181 and EN 15267.
The FWE200DH dust measuring device is designed to continuously measure dust concentrations in wet flue gas. The gas is extracted via a sampling probe and heated above dew point. Droplets in the gas are vaporized, making it impossible for them to falsify the measurement results. The highly sensitive scattered light measurement principle enables even very low dust concentrations to be measured.
The FWE200DH meets the requirements of EN 14181 and EN 15267.
Dust monitor with two measuring principles DUSTHUNTER SP100 - Endress+Hauser
Exhaust gases from cement production or similar applications are usually loaded with dust particles. Environmental protection legislation requires that the dust is removed before the gas is released into the atmosphere.
The Endress+Hauser dust monitor DUSTHUNTER SP100 measures even low dust concentrations and thus detects any filter errors. An automatic zero and reference point check is integrated to reduce the need for maintenance.
The Endress+Hauser dust monitor DUSTHUNTER SP100 measures even low dust concentrations and thus detects any filter errors. An automatic zero and reference point check is integrated to reduce the need for maintenance.
Extractive gas analyzers MCS300P HW - Endress+Hauser
The MCS300P HW is a hot/wet extractive analyzer system for measuring gases.
It detects IR- or VIS-active components with variable measuring ranges for monitoring and regulating combustion processes and exhaust gas purification systems. The heated system components prevent the water and acid dew points from being undercut.
It detects IR- or VIS-active components with variable measuring ranges for monitoring and regulating combustion processes and exhaust gas purification systems. The heated system components prevent the water and acid dew points from being undercut.
Fixed gas analyser MCS100FT - Endress+Hauser
FTIR multi-component analyzing system, for emissions and raw gas monitoring - also with high acid dew point measuring ranges
The FTIR measuring principle allows the simultaneous determination of more than 10 measuring components - tailor made for the particular requirements of the customer. The MCS100FT with its heated measuring cell enables the monitoring of hydrogen fluoride limits as requested by legislation.
The MCS100FT is equipped with an oxygen sensor as standard and can be supplemented with a total hydrocarbon analyzer. With its very reliable measuring technology, its comfortable operation and the low maintenance effort, the MCS100FT provides a careless package that offers unequalled opportunities.
Variants MCS100E CD - Analyzer system with sample gas cooler; MCS100E HW - Analyzer system with hot measurement technology; MCS100E PD - Analyzer system with permeation dryer; MERCEM - Continuous emission monitoring system for mercury.
The FTIR measuring principle allows the simultaneous determination of more than 10 measuring components - tailor made for the particular requirements of the customer. The MCS100FT with its heated measuring cell enables the monitoring of hydrogen fluoride limits as requested by legislation.
The MCS100FT is equipped with an oxygen sensor as standard and can be supplemented with a total hydrocarbon analyzer. With its very reliable measuring technology, its comfortable operation and the low maintenance effort, the MCS100FT provides a careless package that offers unequalled opportunities.
Variants MCS100E CD - Analyzer system with sample gas cooler; MCS100E HW - Analyzer system with hot measurement technology; MCS100E PD - Analyzer system with permeation dryer; MERCEM - Continuous emission monitoring system for mercury.
Fixed gas analysers MAC / GMS 800 - Endress+Hauser
Modular fully configurable system for extractive gas analysis.
The innovative system MAC / GMS 800 is a modular fully configurable system that meets the European Standards EN 15267 and EN 14181 for emission monitoring.
The MAC / GMS 800 versions provide monitoring to meet current directives as well as future requirements, for example emission monitoring in plants with lignite and hard coal firing, gas firing, gas turbines as well as measurement of greenhouse gases.
The innovative system MAC / GMS 800 is a modular fully configurable system that meets the European Standards EN 15267 and EN 14181 for emission monitoring.
The MAC / GMS 800 versions provide monitoring to meet current directives as well as future requirements, for example emission monitoring in plants with lignite and hard coal firing, gas firing, gas turbines as well as measurement of greenhouse gases.
Fixed gas oxigen analyser IN SITU ZIRKOR100 - Endress+Hauser
Oxygen measurement made easy!
The ZIRKOR100 gas analyzer from Endress+Hauser provides robust and reliable oxygen measurement for small combustion plants.
It is characterized by a measurement cell with a long service life and a diagnostic function. This significantly reduces maintenance effort. The ZIRKOR remote app allows you to wirelessly access the analyzer quickly and easily.
The ZIRKOR100 gas analyzer from Endress+Hauser provides robust and reliable oxygen measurement for small combustion plants.
It is characterized by a measurement cell with a long service life and a diagnostic function. This significantly reduces maintenance effort. The ZIRKOR remote app allows you to wirelessly access the analyzer quickly and easily.
Fixed gas oxigen analyser IN SITU ZIRKOR200 - Endress+Hauser
Already has the innovation in the cells!
Endress+Hauser’s ZIRKOR200 gas analyzer provides very robust, reliable, and suitability-tested oxygen measurement for small and large combustion plants.
The ZIRKOR200 is characterized by a measurement cell with a particularly long service life.
Endress+Hauser’s ZIRKOR200 gas analyzer provides very robust, reliable, and suitability-tested oxygen measurement for small and large combustion plants.
The ZIRKOR200 is characterized by a measurement cell with a particularly long service life.
Fixed gas oxigen analyser TRANSIC100LP - Endress+Hauser
TRANSIC100LP is a fixed gas oxigen analyzer from Endress+Hauser ideally suitable for oxygen monitoring in moist and aggressive process gases.
The compact gas spectrometer is based on a tunable diode laser. This measurement technology is well known for unmatched stability and durability. In many applications, the TRANSIC100LP can be flange mounted directly into a process.
This results in real-time measuring values. For processes with high temperatures and pressures or at difficult mounting conditions TRANSIC100LP can be configured with an optional sample cell close to the process in the slip stream.
The compact gas spectrometer is based on a tunable diode laser. This measurement technology is well known for unmatched stability and durability. In many applications, the TRANSIC100LP can be flange mounted directly into a process.
This results in real-time measuring values. For processes with high temperatures and pressures or at difficult mounting conditions TRANSIC100LP can be configured with an optional sample cell close to the process in the slip stream.
Flow meter for measuring air flow in tunnels Flowsic200 - Endress+Hauser
The FLOWSIC200 from Endress+Hauser is used for the contact-free and accurate measurement of flow velocity and flow direction inside tunnels or exhaust ventilation ducts.
Ultrasonic technology provides the cross-sectional mean average value of the flow velocity. This device is used for measurement necessary for optimal ventilation control and reducing running costs to a minimum when air flow is dictated by climatic conditions or by traffic.
Ultrasonic technology provides the cross-sectional mean average value of the flow velocity. This device is used for measurement necessary for optimal ventilation control and reducing running costs to a minimum when air flow is dictated by climatic conditions or by traffic.
Flue gas analyzer portable - testo 340
Flue gas analyzer for use in industry.
Emission checks in industry: Professional technology meets practical design. The testo 340 combustion analyzer is an easy-to-use flue gas analyzer that can be fitted with up to four different gas sensors.
Precise technology: That’s what you want to be able to rely on when you’re working out in the field. But precise technology is nothing if it is not versatile, easy to use and adaptable for use in the field. The testo 340 flue gas analyzer ticks all these boxes.
The testo 340 combustion analyzer. For industrial emission measurements and more.
Emission checks in industry: Professional technology meets practical design. The testo 340 combustion analyzer is an easy-to-use flue gas analyzer that can be fitted with up to four different gas sensors.
Precise technology: That’s what you want to be able to rely on when you’re working out in the field. But precise technology is nothing if it is not versatile, easy to use and adaptable for use in the field. The testo 340 flue gas analyzer ticks all these boxes.
The testo 340 combustion analyzer. For industrial emission measurements and more.
Flue gas analyzer T300 Longlife - Testo
Truly smart flue gas measurement on heating systems with the testo 300 flue gas analyzer. High-quality sensors, intuitive operation with smart-touch technology and smart features, such as efficient documentation and e-mailing of reports, will make your day-to-day work easier.
Free chlorine sensor tecLine CL2 - JUMO
The tecLine CL2 from JUMO is a membrane-covered, amperometric sensor designed to precisely measure free chlorine concentrations in various water types, including drinking water, swimming pool water, industrial water, process water, and cooling water. This sensor can be directly interfaced with compatible display and control units.
Utilizing an amperometric measurement principle with a protective membrane, the sensor effectively detects free chlorine originating from inorganic disinfectants such as chlorine gas (Cl₂), electrolytically generated chlorine, sodium hypochlorite (NaOCl), calcium hypochlorite (Ca(OCl)₂), and chlorinated lime (Ca(OCl)Cl). It is not suitable for confirming the absence of free chlorine.
Utilizing an amperometric measurement principle with a protective membrane, the sensor effectively detects free chlorine originating from inorganic disinfectants such as chlorine gas (Cl₂), electrolytically generated chlorine, sodium hypochlorite (NaOCl), calcium hypochlorite (Ca(OCl)₂), and chlorinated lime (Ca(OCl)Cl). It is not suitable for confirming the absence of free chlorine.
Gas analyser PowerCEMS100 - Endress+Hauser
PowerCEMS100 - High-performance, future-proof CEMS for emission measurement.
The PowerCEMS100 continuous emission monitoring system (CEMS) is an economically and technically perfect solution for extractive measurement tasks. This all-in-one system comprises high-quality standard assemblies and components and can be adapted to the application-specific requirements thanks to its modular system design. Retrofitting analyzer modules or gas conditioners is easy and inexpensive. The innovative PowerCEMS100 system is certified according to European standards EN 15267-1/-3 and EN 14181, and offers future-proof solutions for emission measurement and process applications.
The PowerCEMS100 continuous emission monitoring system (CEMS) is an economically and technically perfect solution for extractive measurement tasks. This all-in-one system comprises high-quality standard assemblies and components and can be adapted to the application-specific requirements thanks to its modular system design. Retrofitting analyzer modules or gas conditioners is easy and inexpensive. The innovative PowerCEMS100 system is certified according to European standards EN 15267-1/-3 and EN 14181, and offers future-proof solutions for emission measurement and process applications.
Gas flow analyzer Flowsic100 Process - SICK
With the FLOWSIC100 Process gas flow measurement devices, measurements can be taken at pressures up to 16 bar – even in zone 2 explosive environments.
The sender/receiver units are available as hermetically sealed designs made of stainless steel or titanium. The standard system contains an MCU control unit and 2 sender/receiver units or a single measuring probe. The MCU is used for signal input and output and to calculate reference values (standardization) or mass flow. It also serves as a user-friendly LCD interface.
The sender/receiver units are available as hermetically sealed designs made of stainless steel or titanium. The standard system contains an MCU control unit and 2 sender/receiver units or a single measuring probe. The MCU is used for signal input and output and to calculate reference values (standardization) or mass flow. It also serves as a user-friendly LCD interface.
Hand-Held Conductivity Measuring Unit HND-C-Kobold
The Kobold hand-held conductivity measuring unit of model HND-C110 is a compact conductivity measuring unit with solidly connected probes that can be used universally. Due to the double display, both, the conductivity and the temperature value can be displayed simultaneously.
The HND-C110 model offers functions like minimum/maximum value memory, hold function, auto-off function, and AutoRange (automatic adjustment of the optimum measuring range). Due to the high temperature dependency in conductivity measurement, the manual measuring unit has automatic temperature compensation. With the improved unit HND-C110, the determination of resistance, salinity, and TDS are also part of the scope of functions.
The HND-C110 model offers functions like minimum/maximum value memory, hold function, auto-off function, and AutoRange (automatic adjustment of the optimum measuring range). Due to the high temperature dependency in conductivity measurement, the manual measuring unit has automatic temperature compensation. With the improved unit HND-C110, the determination of resistance, salinity, and TDS are also part of the scope of functions.
Hand-held pH, redox and temperature measuring units HND-R - Kobold
The Kobold hand-held pH, redox and temperature measuring units of the HND-R106 model are compact and universally applicable measuring units for electrodes with BNC plug connection. An extensive selection of electrodes makes it possible to use the HND-R106 in almost all application areas.
The Kobold HND-R106 measuring unit offers functions like minimum/maximum value memory, hold function, auto off function and automatic temperature compensation. In addition to pH, Redox and temperature measurement, the device can display the relative humidity value. This is calculated from the measured Redox-value and the previously measured or manually entered pH-value.
The Kobold HND-R106 measuring unit offers functions like minimum/maximum value memory, hold function, auto off function and automatic temperature compensation. In addition to pH, Redox and temperature measurement, the device can display the relative humidity value. This is calculated from the measured Redox-value and the previously measured or manually entered pH-value.
IN SITU gas analyser GM32 - Endress+Hauser
The GM32 is a In situ gas analyzer for SO2, NO, NO2, NH3, Temp., O2 (Option)
The GM32 in-situ gas analyzer measures the reactive gases SO2, NO, NO2 and NH3 as well as pressure and temperature in the gas duct - directly, fast and without gas sampling and transport. With this your process systems work with the true values in “real time”. Thanks to self-monitoring you can rely on the measurement results at any time. And in case of a malfunction an early warning will be shown in time. For emission measurement of SO2 and NO, GM32 is tested for suitability according to the new European standard EN 15267-3.
The GM32 in-situ gas analyzer measures the reactive gases SO2, NO, NO2 and NH3 as well as pressure and temperature in the gas duct - directly, fast and without gas sampling and transport. With this your process systems work with the true values in “real time”. Thanks to self-monitoring you can rely on the measurement results at any time. And in case of a malfunction an early warning will be shown in time. For emission measurement of SO2 and NO, GM32 is tested for suitability according to the new European standard EN 15267-3.
IN SITU gas analyser GM35 - Endress+Hauser
GM 35 In situ gas analyzer for carbon monoxide, carbon dioxide and water.
Either simultaneously or as individual measurements: the GM35 measures CO, CO2 and humidity concentrations as well as temperature and pressure quickly, easily and economically. Due to its in-situ measurement technology the GM35 detects the measuring values directly in the gas stream without gas sampling. Reliability, precision and short response time of the analyzer offer a key advantage for efficient control loops in all CO and CO2 generating processes.
Either simultaneously or as individual measurements: the GM35 measures CO, CO2 and humidity concentrations as well as temperature and pressure quickly, easily and economically. Due to its in-situ measurement technology the GM35 detects the measuring values directly in the gas stream without gas sampling. Reliability, precision and short response time of the analyzer offer a key advantage for efficient control loops in all CO and CO2 generating processes.
IN SITU gas analyser GM700 - Endress+Hauser
Measurement of gaseous components under difficult conditions In-situ and extractive technology.
High reliability and precision as well as minimal response times are the distinguishing features of the GM700 Laser gas analyzer. Based on the principle of TDLS and by using specific light absorption the GM700 from Endress+Hauser is able to measure several gas components, such as NH3, HF, O2 or HCl.
The in-situ measurement is ideal for the fast determination of gas concentrations in process control and emission monitoring.
High reliability and precision as well as minimal response times are the distinguishing features of the GM700 Laser gas analyzer. Based on the principle of TDLS and by using specific light absorption the GM700 from Endress+Hauser is able to measure several gas components, such as NH3, HF, O2 or HCl.
The in-situ measurement is ideal for the fast determination of gas concentrations in process control and emission monitoring.
Measuring sensor - CTI-750 - Jumo
Inductive conductivity/concentration and temperature transmitter with switching contacts.
The device is used for measurement/control of the conductivity/concentration of fluid medium. The application is particularly recommended in media in which severe deposits through contamination, oil, grease, or plaster/calcium precipitations are to be expected. The integrated temperature measurement allows a precise and quick temperature compensation that is particularly important when measuring the conductivity. Additional functions, such as the combined toggling of measuring range and temperature coefficient, allow the optimum use in CIP processes.
Two integrated switching outputs can be freely programmed for limit value monitoring of conductivity/concentration and/or temperature. Alarm and control tasks (desalination) can also be assigned.
The device is used for measurement/control of the conductivity/concentration of fluid medium. The application is particularly recommended in media in which severe deposits through contamination, oil, grease, or plaster/calcium precipitations are to be expected. The integrated temperature measurement allows a precise and quick temperature compensation that is particularly important when measuring the conductivity. Additional functions, such as the combined toggling of measuring range and temperature coefficient, allow the optimum use in CIP processes.
Two integrated switching outputs can be freely programmed for limit value monitoring of conductivity/concentration and/or temperature. Alarm and control tasks (desalination) can also be assigned.
Mercury measuring analysers MERCEM300Z - Endress+Hauser
Innovative measurement of mercury in flue gases.
The MERCEM300Z mercury measuring system from Endress+Hauser, monitors Hg emissions in flue gases with high reliability within the smallest measuring ranges (0 ... 10 µg/m³).
Due to its rugged housing, MERCEM300Z is suitable for the use in harsh industrial environments. Thereby the complete extractive system is designed to meet national and international regulations and directives.
The MERCEM300Z mercury measuring system from Endress+Hauser, monitors Hg emissions in flue gases with high reliability within the smallest measuring ranges (0 ... 10 µg/m³).
Due to its rugged housing, MERCEM300Z is suitable for the use in harsh industrial environments. Thereby the complete extractive system is designed to meet national and international regulations and directives.
Multi-channel gas analyzer BIOGAS 905 - Ados
The BIOGAS analyser 905 monitors either continuously or intermittently, the gas components contained in the BIOGAS (process control) and, optionally, monitors the surrounding air to provide an early warning of dangerous, explosive and non-combustible gases and vapours.
Multichannel measuring device for liquid analysis - Aquis Touch S – Jumo
The Jumo AQUIS touch S and P multichannel devices provide a central platform for displaying and further processing a wide variety of measurands in the field of liquid analysis. The devices have a modular design, feature numerous interfaces, and can therefore be adapted entirely according to the individual requirements of each operation. In addition to recording measured values, up to four independent control loops can be implemented. Important process values can also be saved in a tamper-proof manner using an integrated paperless recorder.
Thanks to user-configurable screen masks and a clearly arranged menu navigation, Jumo AQUIS touch S and P are incredibly easy to operate via their touchscreens, despite the wide range of functions.
Thanks to user-configurable screen masks and a clearly arranged menu navigation, Jumo AQUIS touch S and P are incredibly easy to operate via their touchscreens, despite the wide range of functions.
Multitec® BioControl 4/8 – Sewerin
Combined stationary measuring device with mobile gas meter.
The Multitec® BioControl is a combined measuring device consisting of the Multitec® BioControl fixed installation and a mobile gas measuring device, namely the Multitec® 540/545.
Depending on the version of Multitec® BioControl, the gas composition and volume can be automatically measured and monitored at up to eight measurement locations. The Multitec® 540/545 measures the values at the individual measurement locations sequentially. The values are transferred to the Multitec® BioControl via an interface.
The mobile gas measuring device must be regularly maintained to guarantee accurate measuring results. The Multitec® BioControl allows easy maintenance for the versions with four and eight measurement locations as standard, with automatic calibration and adjustment with test gas.
The Multitec® BioControl is a combined measuring device consisting of the Multitec® BioControl fixed installation and a mobile gas measuring device, namely the Multitec® 540/545.
Depending on the version of Multitec® BioControl, the gas composition and volume can be automatically measured and monitored at up to eight measurement locations. The Multitec® 540/545 measures the values at the individual measurement locations sequentially. The values are transferred to the Multitec® BioControl via an interface.
The mobile gas measuring device must be regularly maintained to guarantee accurate measuring results. The Multitec® BioControl allows easy maintenance for the versions with four and eight measurement locations as standard, with automatic calibration and adjustment with test gas.
Optical Sensor for Turbidity Measurements ecoLine NTU - Jumo
The turbidity measurement according to DIN EN ISO 7027 is a tried-and-tested method for monitoring water with low to medium levels of turbidity.
The measuring principle is based on the infrared measurement according to the 90° scattered light method. Due to the light measurement in the wavelength of 880 nm and the wide measuring range of 0 to 4000 NTU the possible uses of the sensor include quality control and assessment of drinking water as well as wastewater control. The Jumo ecoLine NTU saves its calibration data and history directly into its sensor electronics. As a result, the device is quickly set up and ready for use everywhere, without requiring constant recalibration. The sensor design stands out due to its lean and durable construction. In addition, various immersion and flow fittings are available for installation.
The measuring principle is based on the infrared measurement according to the 90° scattered light method. Due to the light measurement in the wavelength of 880 nm and the wide measuring range of 0 to 4000 NTU the possible uses of the sensor include quality control and assessment of drinking water as well as wastewater control. The Jumo ecoLine NTU saves its calibration data and history directly into its sensor electronics. As a result, the device is quickly set up and ready for use everywhere, without requiring constant recalibration. The sensor design stands out due to its lean and durable construction. In addition, various immersion and flow fittings are available for installation.
Particle and flow analyzer Combiprobe CP100 - Endress+Hauser
Combined measurement of dust, volume flow, pressure, and temperature.
The Combiprobe CP100 is the combination of a DUSTHUNTER SP100 scattered light dust measuring device and a FLOWSIC100 PR volume flow measuring device on a flange plate. The combined probe also features a pressure transmitter and a resistance thermometer. The Combiprobe CP100 only requires a single mounting opening in the funnel in order to measure the dust concentration, volume flow, pressure and temperature. This means that there is considerably less outlay on installation than if the individual components were to be installed separately.
The Combiprobe CP100 is the combination of a DUSTHUNTER SP100 scattered light dust measuring device and a FLOWSIC100 PR volume flow measuring device on a flange plate. The combined probe also features a pressure transmitter and a resistance thermometer. The Combiprobe CP100 only requires a single mounting opening in the funnel in order to measure the dust concentration, volume flow, pressure and temperature. This means that there is considerably less outlay on installation than if the individual components were to be installed separately.
Particles analysers DUSTHUNTER SB100 - Endress+Hauser
The DUSTHUNTER SB100 is a type-approved measuring device for dust at very low to high concentrations in challenging applications, e.g. in hot or corrosive gases. The measurement is based on the backward scattering of light. Installation is made from one side only.
Two different penetration depths are possible. Automatic compensation of background light, therefore no light absorber necessary. An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.
Two different penetration depths are possible. Automatic compensation of background light, therefore no light absorber necessary. An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.
pH/Redox single-rod electrodes tecLine - Jumo
Jumo tecLine electrodes are high-quality sensors for professional applications in the process and industrial measuring technology.
The use of high-quality materials and components is the distinguishing feature of these electrodes. They are designed as combined single rod measuring electrodes (glass or metal and reference electrode in one shaft). Depending on the type, an optional temperature probe can also be integrated.
Suitable versions are available to meet the most varied requirements. Jumo tecLine sensors are state-of-the-art for modern pH and Redox electrodes. Each electrode is a high-quality product and individually inspected.
The use of high-quality materials and components is the distinguishing feature of these electrodes. They are designed as combined single rod measuring electrodes (glass or metal and reference electrode in one shaft). Depending on the type, an optional temperature probe can also be integrated.
Suitable versions are available to meet the most varied requirements. Jumo tecLine sensors are state-of-the-art for modern pH and Redox electrodes. Each electrode is a high-quality product and individually inspected.
Portable gas analyser– 310 - Testo
Entry Level' Flue Gas Analyzer
The testo 310 Flue Gas Analyzer combines simple functions with a high level of measurement accuracy, and is perfect for all basic measurements on heating systems.
Long battery lifetimes of up to 10 hours guarantee high availability. It’s easy handling and compact design make the testo 310 a robust tool for daily work – even when things get rough.
The printer specially developed for the testo 310, including infrared interface, allows you to create clear reports on site as required. The current measurement value can be printed out of any measurement menu during or after the measurement.
The testo 310 Flue Gas Analyzer combines simple functions with a high level of measurement accuracy, and is perfect for all basic measurements on heating systems.
Long battery lifetimes of up to 10 hours guarantee high availability. It’s easy handling and compact design make the testo 310 a robust tool for daily work – even when things get rough.
The printer specially developed for the testo 310, including infrared interface, allows you to create clear reports on site as required. The current measurement value can be printed out of any measurement menu during or after the measurement.
Portable, digital pH/redox and conductivity measuring devices 202710 - Jumo
The measuring devices of product group 202710 are battery-operated hand-held units intended to define the following measured values:
pH value, Redox potential and temperature, or conductive conductivity and temperature respectively in laboratories, industrial plants, in waste water treatment, in fish-keeping or fish-farming, etc.
The devices feature a min. and max. value memory and a hold function.
To extend the longevity of the battery, the device can be automatically shut down within a time span of 1 minute to 2 hours. Continuous measuring is also possible. The devices are operated using a membrane keypad.
The devices feature a min. and max. value memory and a hold function.
To extend the longevity of the battery, the device can be automatically shut down within a time span of 1 minute to 2 hours. Continuous measuring is also possible. The devices are operated using a membrane keypad.
Scattered light dust measuring devices DUSTHUNTER SP30 - Endress+Hauser
Measure intelligently. Reduce costs.
The Dusthunter SP30 is a measuring device which reliably detects very low to high dust content.
The measurement is based on the forward scattering of light and is independent of the gas velocity and particle charge. The automated monitoring of the zero and reference point ensures a high level of accuracy.
The Dusthunter SP30 is a measuring device which reliably detects very low to high dust content.
The measurement is based on the forward scattering of light and is independent of the gas velocity and particle charge. The automated monitoring of the zero and reference point ensures a high level of accuracy.
Transmitter for digital or analog interface, digiLine pH/ORP/T – JUMO
This transmitter permits transmission of the measured value from the sensor to the measuring or automation device via digital bus communication or as an analog signal. The digital device version of the transmitter has a 5-pole M12 plug connection – the analog version an 8-pole one.
The 5-pole digiLine electronics supports plug & play operation on the JUMO AQUIS touch S/P or in Modbus operation on the JUMO mTRON T.
The 5-pole digiLine electronics supports plug & play operation on the JUMO AQUIS touch S/P or in Modbus operation on the JUMO mTRON T.
Tunnel analyser - VISIC100SF - Endress+Hauser
The VISIC100SF tunnel analyser is an all-in-one solution for measuring visibility, CO, and NO concentrations. It is the only product of its kind in the world to combine the scattered light measurement principle with electrochemical cells - all in one compact housing.
The VISIC100SF is very easy to mount, operate, and maintain. There is no need for alignment or configuration - so you can start measuring right away. With its IP6K9K enclosure rating, not only is the VISIC100SF able to withstand the harsh ambient conditions inside the tunnel; it can also endure tunnel washing operations without any problems. During the design phase, particular importance was attached to ensuring reliable operation and long maintenance intervals.
The VISIC100SF is very easy to mount, operate, and maintain. There is no need for alignment or configuration - so you can start measuring right away. With its IP6K9K enclosure rating, not only is the VISIC100SF able to withstand the harsh ambient conditions inside the tunnel; it can also endure tunnel washing operations without any problems. During the design phase, particular importance was attached to ensuring reliable operation and long maintenance intervals.
- 0
- 1


